HT Harmonic System

Providing you the best range of ht apfc panel, ht harmonic filter bank detuned, tuned ht harmonic control panel and thyristor control apfc panel with effective & timely delivery.

HT APFC Panel

REQUEST CALLBACK

HT APFC Panel
  • HT APFC Panel
  • HT APFC Panel
  • HT APFC Panel
  • +6 HT APFC Panel
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 6 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Piece
PhaseThree Phase
ApplicationPf improvement/Harmonic
MaterialAluminium
Automation GradeAutomatic
Frequency50 Hz
Voltage3.3/3.6/6.6/11/22/33 KV
Frequency (Hz)50/60Hz
Rated Reactive Power500 to 5000Kvar

APFC Panel is an integration of CRCA powder coated MS Sheet enclosure, fully wired with self-healing HT capacitor, Vacuum contactor, fan, APFCR, all switchgear, with IP protection, busbar AL/CU, with IEC STD.


Additional Information:

  • Item Code: T-HTAPFC
Yes! I am interested

HT Harmonic Filter Bank Detuned

REQUEST CALLBACK

HT Harmonic Filter Bank Detuned
  • HT Harmonic Filter Bank Detuned
  • HT Harmonic Filter Bank Detuned
  • HT Harmonic Filter Bank Detuned
  • +1 HT Harmonic Filter Bank Detuned
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 315 / UnitGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 Unit
Phase3 Phase
Usage/ApplicationIndustrial
Frequency50/60Hz
Rating500 to 6000Kvar
Voltage3.3/6.6/11/22/33 Kv
Mode of SwitchingVCB
ApplicationPF Improvement / Harmonic Reduction

T -HTF bank comprises of HT capacitor and HT reactor assembled in a single star or Double star with protection NCT/RVT along with protection relay.



Additional Information:

  • Item Code: T-HTF
Yes! I am interested

Tuned HT Harmonic Control Panel

REQUEST CALLBACK

Tuned HT Harmonic Control Panel
  • Tuned HT Harmonic Control Panel
  • Tuned HT Harmonic Control Panel
  • Tuned HT Harmonic Control Panel
  • +1 Tuned HT Harmonic Control Panel
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 18 Lakh / PieceGet Latest Price

Product Brochure
Product Details:
Voltage220V
PhaseSingle Phase
MaterialMild Steel
Frequency50 Hz
IP RatingIP54
Frequency Range50HZ
Body MaterialGalvanized Aluminium

We are the leading manufacturer of Harmonic Control Panel. 
Treffer Fast (MV-APFC) are part of the Treffer Factory product and built onmodern Vacuum Contactor -VCC technology. Treffer MV APFC are designed to provideFast reactive power compensation and harmonic filtering in demanding applications.Treffer MV APFC minimise voltage variations and flicker caused by heavy industrialloads, such as Smelting furnaces (MFI), mining motors, Rolling Mill Motors etc.
Yes! I am interested

Thyristor Control Apfc Panel

REQUEST CALLBACK

Thyristor Control Apfc Panel
  • Thyristor Control Apfc Panel
  • Thyristor Control Apfc Panel
  • Thyristor Control Apfc Panel
  • Thyristor Control Apfc Panel
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 1,200 / KVARGet Latest Price

Product Brochure
Product Details:
Minimum Order Quantity1 KVAR
Voltage400/440/480/525/690/800V
BrandTreffer
Usage/ApplicationPf Improvement for dynamic load/ Harmonic Reduction
Frequency50 Hz
KVAr50.....4000Kvar
Country of OriginMade in India

T-RTPFC panel is an integration of CRCA powder coated MS Sheet enclosure , fully wired with Self healing MPP capacitor & Reactor , capacitor duty Thyristor, fan,APFCR, all switchgears, with IP protection , busbar AL/CU, with IEC STD, a) The thyristor switched contactor shall be capable of handling the continuous current of 130% of the rated capacitor current at rated voltage of 415V. The blocking voltage of the thyristor switch during off Condition should be minimum 1800 Volt peak. Every thyristor switch should be capable of handling the dv/dt of 2000 Volts/ S. b) The thyristor switched contactor used shall turn on at zero differential voltage across it. This zero differential voltage tolerance shall not exceed 6 Volts peak value around zero. c) The time delay between turn off and subsequent turn on should be as minimum as possible and in the range of milliseconds. There should not be any discharge devices across capacitor that can exceed the watt loss of more than 30 watt.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
P. S. Bisale (Managing Director)
Treffer Power System Solution Private Limited
Gat No. 1538, Dehu Alandi Road, Tal. Haveli, Chikhali
Pune - 411062, Maharashtra, India